| Name/Model: |
Closed-loop Hall current sensor CHB-6MP, 15MP, 25MP |
| Rated input Parameter: |
DC, AC or pulsed 6A~25A current / PCB |
|
|
SENSOR MODULE CHB-6MP, 15MP, 25MP |
|
The SENSOR Module CHB-6MP~25MP is a closed loop Hall current sensor to measure 6A…25A DC, AC |
|
or pulsed currents with a galvanic isolation between the primary and secondary circuits. |
|
|
|
Closed-loop Hall Current Sensor: |
|
Type |
Nominal current |
Output voltage |
Accuracy |
Supply voltage |
Aperture |
|
IN(A) |
VM(V) |
X(%) |
Vc(V) |
mm |
|
CHB-6MP |
6 |
2.5±0.625 |
±0.7% |
+5 |
6.6X4.3 / PCB |
|
CHB-15MP |
15 |
2.5±0.625 |
±0.7% |
+5 |
6.6X4.3 / PCB |
|
CHB-25MP |
25 |
2.5±0.625 |
±0.7% |
+5 |
6.6X4.3 / PCB |
|
|
|
Specifications: |
|
Principle |
Closed loop Hall effect principle |
|
Input current |
6…25A(DC、AC、Pulsed current) |
|
Output voltage |
2.5±0.625V |
|
Turns ratio |
1:960(6A), 1:1200(15A), 1:2000(25A) |
|
Frequency |
DC~100KHz |
|
Accuracy |
±0.7% |
|
Response time |
<500nS |
|
Linearity |
<0.1% |
|
Supply voltage |
±12~15V(±5%) |
|
Consumption |
28mA |
|
Isolation voltage |
Between primary and secondary circuit: 2.5KV RMS/50Hz/1min. |
|
Operating temp. |
-25…+85℃ |
|
Mounting on |
PCB |
|
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
|
For industry |
electronic power system, railways, rectifiers systems etc. |
|
>>Back |
|
| |
|
|